- Unit/Units
- 1
- Unit/Units
- 360000.00 INR
- Clinical,Veterinary,Path Lab,Research,Hospital
- Hospital
- Fully Automated Haematology Analyser
We have earned a reputation of dignified manufacturer, exporter and supplier of high quality Fully Automated Haematology Analyser. The analyser provided by us is designed and manufactured in line with set international standards using quality-approved components and latest methodology. Offered analyser counts the number of red & white blood cells, blood platelets, haemoglobin and haematocrit level in a blood sample. In addition, our prestigious customers can avail this Fully Automated Haematology Analyser in various technical specifications at market leading prices.
Features:
- Robust construction
- Compact design
- Accurate result
- High operational fluency
Specifications:
- Fully Automated Haematology Analyser
- Our all products having in product quality accreditation like ISO-9001,ISO-14001,ISO- 13485,CE,WHO-GMP & FDA
- 3 Part differential Cell Counters
- General Technical Specifications Principles Electrical resistance for counting and SFT method for hemoglobin. Parameters WBC, Lymph, Mid, Gran, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, WBC Histogram, RBC Histogram, PLT Histogram, P-LCR. Working mode Single counting pathway + Independent HGB detection system Operating mode Color Windows interface, figure button, mouse input Specification 23 parameters, with 3 part WBC differntial Aperture Diameter 70um 10 uL sampler volume Memory for 30,000 results including histograms Throughput: 35 samples/hour Automatic and manual calibration Automatic dilution when power on/off High voltage cleaning after each measurement QC mode: X-B, L-J curve, SD, CV Interface 1 parallel interface, 2 USB
General Technical Specifications
Principles
- Electrical resistance for counting and SPT methods for hemoglobin.
Parameters
- WBC, Lymph, Mid Gran, Lymph %, Mid %, Gran %, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, PLT, MPV, PDW, PCT, WBC Histrogram, RBC Histrogram, PLT Histrogram, P-LCR.
- Working mode: Double counting pathway + independent HGB detection systems
- Operating mode: Color Windows interface, figure button, mouse input.
- Interface: 1 parallel interface, 2 USB interfaces, 2 RS232 interfaces (with net), 1 VGA interface.
Specification
- 23 parameters with 3 part WBC differential
- Aperture Diameter volume
- 10 ul sampler volume
- Memory for 30,000 results including histograms
- Throughput : 60 samples / hour
- Automatic and manual calibration
- Auomatic dilution when power on / off
- High voltage clednind after each measurement
- QC mode : X-B, L-J curve, SD, CV.
Performance
Parameter | Linearity range | Precision |
WBC | 0.5-99.9x10/L | CV<2.0% |
RBC | 0.2-9.99x10/L | CV<1.5% |
HGB | 1.0-299.9 g/L | CV<1.5% |
MCV | 40-200.0 fL | CV<0.5% |
PLT | 0 999x10/L | CV<4.0% |
- Carryover: WBC < 0.5 %, RBC < 0.5 %, PLT < 2 %
- Operating Environment: Temperature 15 degree C 30 degree C
- Humidity 10% 85 %
- Printout: Thremal recorder, printer, Optional external printer
- Display: Large color LCD display, resolutions 640 x 480 dot
- Power Requirement 175-265v 50 / 60HZ
- Weight: 25 Kg
- 1 Per Week
- 1 Week
Sales Office- 404 /405, Shantidham Heights, New Parsik Service Road, Parsik Nagar, Kalwa West, Thane, Maharashtra, 400605, India